Innovac GmbH Used machines from Germany
Innovac maszyny-uzywane Testowanie materiału [1 - 17 of 17]
Reometr-Alpha-Technologies-RPA-2000 używany
Reometr
Alpha Technologies RPA 2000
Niemcy
nieznany
używany
na żądanie
INNO30176
An Alpha rubber process analyzer for testing the rheological and dynamic properties of elastomers and rubber compounds is available. Frequency range: 0.1-3000cpm, max. temperature: 230°C, max. heating rate: 1°C/s, max. cooling rate: 0.5°C/s, max. strain: +/-90°, test standards: ASTM D5289/D6048/D6204/D6601/D7050/D7605/D8059. Machine dimensions X/Y/Z: approx. 800mm/700mm/1350mm, weight: approx. 200kg. Including PC with Eclipse software and spare parts. Documentation available. On-site inspection possible.
Miernik-lepkości-Alpha-Technologies-MV2000 używany
Miernik lepkości
Alpha Technologies MV2000
Niemcy
nieznany
używany
na żądanie
INNO30175
An Alpha viscometer for testing raw elastomers and rubber compounds is available. Test standards: ASTM D1646/D3346, max. temperature: 200°C, rotational speed: 2rpm. Machine dimensions X/Y/Z: approx. 800mm/700mm/1350mm, weight: approx. 200kg. Without software. Documentation available. An on-site inspection is possible.
Reometr-Alpha-Technologies-MDR-2000 używany
Reometr
Alpha Technologies MDR 2000
Niemcy
nieznany
używany
na żądanie
INNO30174
A Moving Die Rheometer Alpha for rheological testing and vulcanization analysis of rubber compounds is available. Test standards: ASTM D5289/ISO6502, max. temperature: 200°C, frequency: 1667Hz, strain: 0.2°/0.5°, test pressure: 8000kPa. Machine dimensions X/Y/Z: approx. 800mm/700mm/1350mm, weight: approx. 200kg. Without software. Documentation available. An on-site inspection is possible.
System-kontroli-rentgenowskiej-Mekitec-Meki-D4 używany
System kontroli rentgenowskiej
Mekitec Meki D4
Niemcy
2015
używany
na żądanie
INNO30074
An X-ray inspection device Mekitec for the food industry is available. Measurement device type: Rad Eye B20, max. power: 60kV/1.66mA/100W, method: inline inspection, test object: packaged food products, tunnel clearance X/Y: approx. 250mm/100mm, belt length: 1200mm, belt width: 250mm, max. belt speed: 1.3m/s, max. product weight: 5kg, machine dimensions X/Y/Z: approx. 2000mm/550mm/1200mm, weight: approx. 100kg. Documentation available. An on-site inspection is possible.
Szafa-grzewcza-Binder-ED-400-KBF-115 używany
Szafa grzewcza
Binder ED 400/KBF 115
Niemcy
nieznany
używany
na żądanie
INNO30014
Two drying and heating ovens Binder for laboratory use are available. 1) Binder ED 400, usable volume: 400L, internal dimensions X/Y/Z: 1000mm/800mm/520mm, levels: 2, max. load per level: 35kg, max. total load: 90kg, recommended wall clearance rear/side: 160mm/100mm, max. temperature variation: +/-3K, max. temperature: 300°C, power: 3.4kW, machine dimensions X/Y/Z: approx. 1250mm/1050mm/800mm, weight: approx. 125kg. 2) Binder KBF 115, usable volume: 100L, max. temperature: 100°C, power: 1.7kW. Documentation available. An on-site inspection is possible.
Twardościomierz-Mitutoyo-Durotwin-Plus-963 używany
Twardościomierz
Mitutoyo Durotwin Plus 963
Niemcy
nieznany
używany
na żądanie
INNO29919
Scales: Rockwell/Rockwell Superficial, max. workpiece height: approx. 180mm, max. test depth: approx. 165mm, dwell time: approx. 3s, data output: Digimatic/RS-232-C, machine dimensions X/Y/Z: approx. 250mm/520mm/780mm, weight: approx. 50kg. Documentation available. An on-site inspection is possible.
Piekarnik-uniwersalny-Memmert-UF30 używany
Piekarnik uniwersalny
Memmert UF30
Niemcy
2020
używany
na żądanie
INNO29819
Operating temperature: 10-300°C, setting temperature: 20-300°C, setting accuracy: up to 99.9°C: 0.1°C, from 100°C: 0.5°C, temperature sensor: 1x Pt100 DIN class A, 4-wire measurement, control: Control COCKPIT Single DISPLAY, digital PID microprocessor controller with TFT color display, timer: 1 minute to 99 days, functions: SetpointWAIT, calibration of 3 temperature values, parameter selection (temperature, circulating air motor, exhaust air, program runtime, time zones), electronically controllable air turbine adjustable in 10% steps, fresh air via adjustable exhaust flap with preheating, exhaust port with throttle valve electronically controllable, logging: storage in case of power failure, programming: data logger evaluation via Ethernet, AtmoCONTROL software optional via USB, safety: electronic temperature monitoring, mechanical limiter TB, protection class 1 (DIN 12880), self-diagnosis system, internal dimensions: 400x320x250mm, volume: 32l, max. inserts: 3, max. load: 60kg, max. load per insert: 20kg, length: 650mm, width: 660mm, height: 890mm, weight: 45kg. The oven has hardly been used. An on-site inspection is possible.
Automatyczny-system-kontroli-rentgenowskiej-Anritsu-XR-75-KXS7522AVCLE używany
Automatyczny system kontroli rentgenowskiej
Anritsu XR 75 (KXS7522AVCLE)
Niemcy
2016
używany
na żądanie
INNO28620
An almost new Anritsu X-ray inspection system is available. X-ray power: 100W, max. detection width: 240mm, max. detection height: 120mm, detection speed from 2kg to 5kg: 10m-60m/min, detection speed up to 2kg: 60m-90m/min, detection speed from 5kg to 10kg: 10m-40m/min, housing material: stainless steel, machine weight: approx. 255kg, operating hours: less than 50h. The machine shows no wear on the conveyor belt or the radiation protection curtains. Documentation available. On-site inspection is possible.
Twardościomierz-Zwick-3202 używany
Twardościomierz
Zwick 3202
Niemcy
1969
używany
na żądanie
INNO27522
Lens magnification: 20x, aperture: 0.35, total magnification: 200x, measuring accuracy: +/-4kp/mm², average hardness value D: 144kp/mm², average thickness of reference plate: 5.9mm, max. test height: 300mm, throat depth: 135mm, machine dimensions X/Y/Z: approx. 450mm/450mm/600mm, weight: approx. 60kg. Including various lenses, clamping device for round specimens, hardness comparison plates and more. Documentation available. On-site inspection is possible.
Szafa-klimatyczna-Memmert-UL-800Ü używany
Szafa klimatyczna
Memmert UL 800Ü
Niemcy
nieznany
używany
na żądanie
INNO28332
A Memmert universal heating oven for laboratory and test procedures is available. Nominal temperature: 180°C, internal dimensions X/Y/Z: 1040mm/1200mm/600mm, internal volume: 750l, output: 6.2kW, external dimensions X/Y/Z: approx. 1200mm/1650mm/750mm, weight: approx. 200kg. On-site inspection is possible.
Automatyczny-system-kontroli-rentgenowskiej-Anritsu-XR75 używany
Automatyczny system kontroli rentgenowskiej
Anritsu XR75
Niemcy
2018
używany
na żądanie
INNO27312
A complete Anritsu X-ray system for packaged products is available. 1) X-ray unit KXS7534AVCLE: Tube voltage: 30kV-80kV, tube current: 0.4mA-3.3mA, output power: 12W-100W, detection width/height: 390mm/220mm, belt width: 420mm, belt speed: 10m/60m/min, max. belt load: 5kg, ambient temperature: 0°C-35°C, relative humidity: 30%-85%, weight: approx. 300kg. 2) Metal separator KDS450ABW: working width: 450mm, working height: 95mm. 3) Metal separator KW466CW: max. product dimensions X/Y/Z: 350mm/200mm/30mm (100mm for regular interval), max. product weight: 500g, max. output: 80 products/min. 4) Material feed through Jöst FDL 350/60x500 vibratory feeder. Documentation available.
Hydrauliczny-system-testowy-Niehues-DN200-DN600 używany
Hydrauliczny system testowy
Niehues DN200-DN600
Niemcy
2019
używany
na żądanie
INNO27302
A Niehues hydraulic testing system is available. 1) TP pump, motor power: 315kW, liter capacity: 13.94l-41.83l/min, max. operating pressure: 25bar, nominal delivery head: 28m. 2) NKG pump, motor power: 315kW, liter capacity: 5.61l-16.83l/min, max. operating pressure: 16bar, nominal delivery head: 80.7m. 3) Tank, volume: 11400l, permissible pressure: 0.5bar-10bar, operating pressure min./max.: 1bar-5.5bar, medium: drinking water without additives, temperature min./max.: -10°C-50°C, permissible load rating: 1000.
Komora-do-badań-klimatycznych-Feutron-Klimasimulation-KPK-900l używany
Komora do badań klimatycznych
Feutron Klimasimulation KPK 900l
Niemcy
2008
używany
na żądanie
INNO26599
Test chamber volume: 900 l, Temperature range: -40°C - +100°C, humidity range: 10 - 98, Test chamber weight: 750kg, refrigeration system weight: 480kg. Refrigerant, refrigerant quantity and operating pressure: R134a/0.8kg/18bar, R507/4.0kg/27bar, R23/1.0kg/27bar
System-wykrywania-pęknięć-K+d-Flux-technic używany
System wykrywania pęknięć
K+d Flux-technic
Niemcy
nieznany
używany
na żądanie
INNO26245
Functions according to the magnetic particle technology, with documentation and accessories, an inspection is possible.
Reometr-Göttfert-ELASTOGRAPH-67.85 używany
Reometr
Göttfert ELASTOGRAPH 67.85
Niemcy
1987
używany
na żądanie
INNO26128
Rotorless rotational shear vulcameter with filter mats, calibration weights, new stepper motor and documentation. The device has been recalibrated and the chamber renewed, control unit has been replaced with a standard PC connection, on-site inspection is possible.
Maszyna-do-badania-twardości-Otto-Wolpert-werke-DiaTestor-3a używany
Maszyna do badania twardości
Otto Wolpert-werke DiaTestor 3a
Niemcy
1973
używany
na żądanie
INNO25083
Max. test load range: 750kg, with documentation and accessories.
Tester-materiałów-Netzsch-DMA-GABO-Eplexor-4000N używany
Tester materiałów
Netzsch DMA GABO Eplexor 4000N
Niemcy
2009
używany
na żądanie
INNO23733
Max. static force: 4000N, max. dynamic force: +/-4000N, temperature range: -160 to 500°C, including accessories, was last calibrated in 2020.