Combined-Heat-and-Power-Plant-Jenbacher-Stamford-JMS-612-GS-N.L used
Combined Heat and Power Plant
Jenbacher/ Stamford JMS 612 GS-N.L
Germany
2020
used
on request
INNO32219
1) Four-stroke engine Jenbacher J 612 GS-J03, operating hours: under 15,000h, ISO standard output: 2,058kW, design: V 60°, number of cylinders: 12, bore: 190mm, stroke: 220mm, displacement: 74.85l, input power: 4,474kW, mixture: 692kW, oil: 204kW, engine cooling water: 315kW, exhaust gas when cooled to 180°C: 638kW, exhaust gas when cooled to 100°C: 909kW, surface heat: 79kW, rated speed: 1,500/min, moment of inertia: 56.67kgm², direction of rotation (viewed from flywheel): left, radio interference suppression level acc. to VDE 0875: N, starter power: 13kW, starter voltage: 24V, mean piston speed: 11m/s, length: 4,246mm, width: 1,886mm, height: 2,503mm, engine dry weight: 9.5t, engine operating weight: 10.3t, 2) Generator Stamford LVSI 804 W, rated output: 2,643kVA, drive power: 2,058kW, rated active power cos φ=1: 2,004kW, rated active power cos φ=0.8: 1,986kW, rated apparent power cos φ=0.8: 2,483kVA, rated reactive power cos φ=0.8: 1,490kVA, rated current at cos φ=0.8: 3,584A, frequency: 50Hz, voltage: 400V, speed: 1,500/min, overspeed: 1,800/min, power factor (ind.-cap.): 0.8-0.95, efficiency cos φ=1: 97.4%, efficiency cos φ=0.8: 96.5%, moment of inertia: 117kgm², cable outlet: left, insulation class: H, temperature rise (at drive power): F, max. permissible ambient temperature: 40°C, weight: 6.752t, with documentation. An on-site inspection is possible.
Combined-Heat-and-Power-Plant-Mtu-GC-201-N5 used
Combined Heat and Power Plant
Mtu GC 201 N5
Germany
2012
used
on request
INNO31901
Heating output: 275kW, electrical output: 201kW, fuel: natural gas, engine: MTU E 3066 L3, engine cylinders: 6, overall efficiency: approx. 82%, generator rating: 276kVA, machine dimensions X/Y/Z: approx. 3550mm/1800mm/2100mm, weight: approx. 4500kg, operating hours: approx. 57557h. Documentation available. An on-site inspection is possible.
Combined-Heat-and-Power-Plant-Kw-Energie-smartblock-50 used
Combined Heat and Power Plant
Kw Energie smartblock 50
Germany
2016
used
on request
INNO29921
Fuel: natural gas (NG), engine: HMG, space heating unit with CHP: yes, condensing boiler: no, additional heating unit: no, low-temperature boiler: no, B11 boiler: no, combi unit: no. Rated heat input P: 88kW, annual efficiency of the space heating system η: 136%, energy efficiency class: A++, usable heat output at rated heat input with additional heater switched off/on: 87.9kW, thermal efficiency at rated heat input with additional heater switched off/on: 57.5%, electrical efficiency at the heat output of the space heating unit with CHP with additional heater switched off/on: 33.5%, auxiliary power consumption at full load/part load el: 1.132kW, in standby mode P SB: 0.06kW, standby heat loss P stby: 0.442kW, annual energy consumption Q HE: 1345kWh, sound power level indoors L WA: 72dB, operating hours: 42,892h. Water was detected in the oil circuit, the unit has an oil-related fault despite sufficient oil being present, and it also shuts down with the message engine too hot. The control unit was overhauled by the manufacturer in 2024, and regular maintenance intervals for oil changes, spark plugs, valves, etc. have been carried out. With documentation.
Combined-Heat-and-Power-Plant-Man-daimler-Benz-krauter-12-Zylinder-8-Zylinder used
Combined Heat and Power Plant
Man/daimler Benz/krauter 12 Zylinder/8 Zylinder
Germany
unknown
used
on request
INNO27139
A combined heat and power unit (CHP), consisting of three diesel generators installed in containers, is available. 1) Engine: MAN 12-cylinder turbo, type: D 2842 LE 20, generator: Krauter, type: D-SYN-GEN, kVA: 400, kW: 360, A: 577, Hz: 50, speed: 1500 rpm. Including DELF synchronization, heating water outlet, table cooler, preheating and oil change device. 2) Engine: MAN 12-cylinder turbo, type: D 2842 LE 20, generator: Leroy-Somer, type: LSA K 475 L10, kVA: 375, kW: 300, A: 400, Hz: 50, speed: 1500 rpm. Including DELF synchronization, heating water outlet, table cooler, preheating and oil change device. 3) Engine: Daimler Benz 8-cylinder turbo, type: AGV 12, generator: Krauter, type: D-SYN-GEN, kVA: 350, kW: 230, A: 400, Hz: 50, speed: 1500 rpm. The combined heat and power unit has a total output of around 1100kVA. Including table cooler, V2A heat exchanger, containers and switch cabinets. All generators are installed in containers and are therefore easy to transport.
Combined-Heat-and-Power-Plant-Senertec-Dachs-G-5.5 used
Combined Heat and Power Plant
Senertec Dachs G 5.5
Germany
2011
used
on request
INNO26721
Electrical output: 5.5kW, thermal output: 14.8kW, max. heat output: 20.5kW. max. flow temperature: 95°C, max. return temperature: 70°C, operating pressure: 5bar. Dimensions X/Y/Z without controller: approx. 1000mm/720mm/1070mm, weight: 530kg, operating hours: 66,773h, fuel: natural gas. Including condenser and MSR 2 control. Documentation available.
Generator-Leroy-Somer-TA-2800-M8 used
Generator
Leroy Somer TA 2800 M8
Germany
1977
used
on request
INNO21859
Runs with diesel and vegetable oil, power: 180kW, connected load: 200kVA, weight: 920kg, was overhauled in 2004.
Combined-Heat-and-Power-Plant-Herford-Marelli used
Combined Heat and Power Plant
Herford/ Marelli
Germany
unknown
used
on request
INNO20689
System includes (1) Two-Cylinder Motor HERFORD 2H 280, power: 150PS, rotational speed: 400/min, electric/ heating power: 83/ 140kWh, with Generator MARELLI MJB 250 LE4 (2) Three-Cylinder Motor HERFORD 3H 280, power: 225PS, rotational speed: 400/min, electric/ heating power: 125/ 212kWh, with Generator MARELLI MJB 250 MA4.