Innovac GmbH Used machines from Germany
Innovac used-machines Energy management [21 - 40 of 156]
Chiller-Climaveneta-TECS-H-1AS used
Chiller
Climaveneta TECS-H-1AS
Germany
2006
used
on request
INNO26139
Three identical chillers are available, refrigerant: R134a, connected load: 80kW weight: 1.44t, on-site inspection is possible.
Three-Phase-Cast-Resin-Transformer-Abb-DTE-1250-24 used
Three-Phase Cast Resin Transformer
Abb DTE 1250/24
Germany
2004
used
on request
INNO26125
Power: 1250kVA, max. voltage: 21kV, max. current: 120.28A, weight: 3.79t, without spare parts, accessories or documentation, an on-site inspection is possible.
Screw-Compressor-Kaeser-SK-25 used
Screw Compressor
Kaeser SK 25
Germany
1986
used
on request
INNO26079
There are two identical screw compressors available, operating pressure: 7.5bar, max. pressure: 8bar, volume flow: 0,82-2,57m³/min, width: 750mm, length: 895mm, height: 1260mm, weight: 337kg, were completely overhauled and always serviced.
Immersion-Recooler-Hyfra-TRK90-ÖF-S used
Immersion Recooler
Hyfra TRK90-ÖF-S
Germany
2011
used
on request
INNO26047
Four Hyfra TRK90-ÖF-S are available, cooling capacity: 11.6kW, max. ambient temperature: 42°C, connected load: 9.8/11.3kW, weight: 170kg.
Tooth-Compressor-Atlas-Copco-ZR-45 used
Tooth Compressor
Atlas Copco ZR 45
Germany
1994
used
on request
INNO26002
There are two identical compressors available, max. final pressure: 8bar, rotational speed: 3000/min, motor power: 45kW, operational hours counter: ca. 80,000h, each with a Dry Air Dryer Atlas Copco MD 100W.
Clean-Room-Ventilation-System-Weiss-Klimatechnik-Ultraclean-120.3-DXD used
Clean Room Ventilation System
Weiss Klimatechnik Ultraclean 120.3 DXD
Germany
2007
used
on request
INNO25995
Volume flow: 7650m³/h, heating output: 21kW, connected load: 87kVA, weight: 960kg.
Clean-Room-Ventilation-System-Weiss-Klimatechnik-WKT2N-KOMBI-96 used
Clean Room Ventilation System
Weiss Klimatechnik WKT2N KOMBI 96
Germany
2014
used
on request
INNO25994
Volume flow: 3000m³/h, coolant capacity: 20kg, coolant output: 43.8kW, weight: 1.27t.
Gas-Burner-Weishaupt-WM-G20-3-A used
Gas Burner
Weishaupt WM-G20/3-A
Germany
2013
used
on request
INNO25945
Power: 300-2000kW, with gas pressure regulator FRS 520 Dungs and solenoid valve Dungs.
Gas-Burner-Weishaupt-WM-G20-3-A used
Gas Burner
Weishaupt WM-G20/3-A
Germany
2013
used
on request
INNO25944
Power: 300-2000kW, with gas pressure regulator FRS 520 Dungs and solenoid valve Dungs.
Air-Heater-G.-Maier-Elektrotechnik-LH-K-500-500-1300-140kW-3-400-PT used
Air Heater
G. Maier Elektrotechnik LH/K 500/500/1300/140kW/3/400/PT
Germany
2022
used
on request
INNO25917
Heating output: 140 kW, heating output switched in 4 stages of 35 kW each, air volume flow of 6500 m³/h, air speed of 9.8 m/s, stainless steel tubular heating element (1.4828) with a surface load of 3.9 W/cm², inlet temperature: approx. 20°C, outlet temperature: approx. 160°C, temperature sensor PT100, EC declaration of conformity. Two identical air heaters are available, with documentation, the heaters are still unused, an on-site inspection is possible.
Generator-Siemens-GEN-1FC2-353-4LB49 used
Generator
Siemens GEN 1FC2 353-4LB49
Germany
1998
used
on request
INNO25903
Nominal power: 400kVA, rotational speed: 1500/min, weight: 1.27t.
Transformer-Serem-IRNH used
Transformer
Serem IRNH
Germany
1969
used
on request
INNO25902
Nominal load: 250kVA, weight: 1.28t.
Transformer-Trafo-union-TS-5444-B used
Transformer
Trafo-union TS 5444 B
Germany
1980
used
on request
INNO25901
Nominal load: 250kVA, weight: 950kg.
Screw-Compressor-Kaeser-DB-165C used
Screw Compressor
Kaeser DB 165C
Germany
2005
used
on request
INNO25822
There are two identical screw compressors available, volume flow machine 1/ 2: 11.85/ 14.41m³/min, nominal rotational speed machine 1/ 2: 3780/ 4450/min, motor power: 15kW, one machine has a star-delta control, one is frequency-controlled, one machine is to be considered defective due to bearing damage on the main motor, a bearing to repair the motor would be available, on the other one the frequency converter is defective.
Screw-Compressor-Atlas-Copco-GA26-VSG+ used
Screw Compressor
Atlas Copco GA26 VSG+
Germany
2016
used
on request
INNO25808
Power: 16kW, operational hours counter: 12,468h, with refrigerant dryer and documentation, was maintained regularly.
Absorption-Refrigerator-Carrier-SCS-16LJ-03E-LC used
Absorption Refrigerator
Carrier SCS 16LJ-03E-LC
Germany
2016
used
on request
INNO25798
Absorption Refrigerator System with cooling tower Karlsruhe KRD 1/12-28-3. Cooling output: 214kW, permissible temperature: 10-60°C, max. overpressure: 1bar, nominal volume flow: 87.1m³/h, with Radial Fan Wolter GmbH TRZ 900/80 KTK and Absorption Chiller Carrier SCS 16LJ-03E-LC.
Screw-Compressor-Atlas-Copco-GA30 used
Screw Compressor
Atlas Copco GA30
Germany
unknown
used
on request
INNO25749
An inspection is possible.
Generator-Atlas-Copco-QAS-60 used
Generator
Atlas Copco QAS 60
Germany
unknown
used
on request
INNO25724
Power: 60kVA, length: 2730mm, width: 1100mm, height: 1795mm, weight: 1.525t, operational hours counter: 5559h.
Oil-Gas-Low-Temperature-Heating-Boiler-Viessmann-Paromat-ER-ND used
Oil/Gas Low Temperature Heating Boiler
Viessmann Paromat-ER-ND
Germany
1998
used
on request
INNO25658
There are two identical Viessmann Paromat-ER-ND available, nominal oil/gas output: 460kW, max. rated power input: 1000W, were maintained regularly.
Gas-Insulated-Medium-Voltage-Installation-Siemens-8DJH used
Gas Insulated Medium Voltage Installation
Siemens 8DJH
Germany
2019
used
on request
INNO25632
Includes (1) panel 1 8DJH-L, dimensions: 2000x430x800mm, rated voltage: 24kV, operating voltage: 20kV, rated current: 250A, with 1x feeder panel IN=630A, 1x load-break switch and circuit-breaker panel IN=250 A, UMZ protection, etc., 1 SF6 leakage monitor with manometer. MCA 4, voltage and current measurement by means of transformer interlocked with pressure-resistant cable box, pressure relief channel, 1 SF6 leakage monitor with manometer (2) panel 2 8DJH-L, dimensions: 2000x430x800mm, rated voltage: 24kV, operating voltage: 20kV rated current: 250A, with 1x transformer outgoing panel IN=630A, 1x switch-disconnector and circuit-breaker panel IN=630 A, UMZ protection, MCA 4, interlocked with flameproof cable box pressure relief duct and 1 SF6 leakage monitor with manometer (3) Panel 3 8DJH-V, dimensions: 1800x430x800mm rated voltage: 24kV, operating voltage: 20kV, rated current: 250A, with 1x transformer feeder panel IN=630A, 1x switch disconnector and circuit breaker panel IN=630A, interlocked with flameproof cable box, pressure relief channel and 1 SF6 leakage monitor with pressure gauge (4) Panel 4 8DJH-R, dimensions: 2000x310x800mm, rated voltage: 24kV, operating voltage: 20kV, rated current: 630A, with 1x ring cable branch, 1x switch-disconnector IN=630A, interlocked with flameproof cable box, pressure relief channel, 1 SF6 leakage monitor with pressure gauge, panel assembly (5) Panel 5 8DJH-L, dimensions: 2000x430x800mm, rated voltage: 24kV, operating voltage: 20kV, rated current: 250A, with 1x transformer feeder panel IN=630 A, 1x switch-disconnector and circuit-breaker panel IN=630 A, UMZ protection etc. MCA 4, interlocked with flameproof cable box, pressure relief channel and 1 SF6 leakage monitor with pressure gauge.